Stent recanalization of carotid tonsillar loop dissection using the Enterprise vascular reconstruction device

Rahal JP, Gao B, Safain MG, Malek AM.

J Clin Neurosci 21(7):1141-7, 2014.

PMID 24642024 · DOI 10.1016/j.jocn.2013.11.007 · PMCID PMC4141559

In plain language

A dissection is a tear in the inner lining of an artery that can narrow or block it. In the neck, the internal carotid artery sometimes forms a tight, twisting loop called a tonsillar loop, and this sharp curve makes it hard to use standard carotid stents (small mesh tubes that hold an artery open).

Angiograms before and after stenting in five patients with a torn, looping carotid artery in the neck, showing the artery reopened in each.
Angiograms before and after stenting in five patients with a torn, looping carotid artery in the neck, showing the artery reopened in each.Figure 1 from Rahal JP et al. J Clin Neurosci, 2014. © Elsevier.

Over 12 years, 9 of 48 patients with neck carotid dissections had a tonsillar loop, and 5 needed treatment through a catheter. The team used the Enterprise, a thin, flexible stent delivered through a very small catheter. Four nearly blocked arteries were reopened in the acute phase, and narrowing improved from 90% to 31% on average. There were no strokes, mini-strokes or deaths from the procedure. Over about 28 months of follow-up, all stents stayed open and no patient worsened, though one stent kinked at the sharpest bend.

The authors note that this stent's low outward force and risk of kinking deserve consideration.

A plain-language summary for patients and families. It is not medical advice, and individual results vary.

Abstract

Although advances in endovascular techniques have permitted reconstruction of intimal dissections and related pseudoaneurysms of the extracranial cervical internal carotid artery, highly tortuous tonsillar loop anatomic variants still pose an obstacle to conventional extracranial self-expanding carotid stents. During a 12 year period, nine of 48 cases with cervical carotid dissections were associated with a tonsillar loop. Five patients required endovascular treatment, which was performed using a microcatheter-based technique with the low-profile Enterprise vascular reconstruction device (Codman Neurovascular, Raynham, MA, USA). Technical, radiographic, and clinical outcomes were analyzed for each patient. Dissection etiology was spontaneous in three patients, iatrogenic in one, and traumatic in one. Four near-occlusive tonsillar loop dissections were successfully recanalized during the acute phase. Dissection-related stenosis improved from 90±22% to 31±13%, with tandem stents needed in three instances to seal the inflow zone. There were no procedure-related transient ischemic attacks (TIA), minor/major strokes, or deaths. Angiographic follow-up for a mean of 28.0±21.6 months showed all stents were patent, with average stenosis of 25.2±12.2%. Focal ovalization and kinking of the closed-cell design was noted at the sharpest curve in one patient. Clinical outcome (follow-up of 28.1±21.5 months) demonstrated overall improvement with no clinical worsening, new TIA, or stroke. Tonsillar loop-associated carotid dissections can be successfully and durably recanalized using the low-profile Enterprise stent with an excellent long-term patency rate and low procedural risk. The possibility of stent kinking and low radial force should be considered when planning reconstruction with this device.

Abstract as indexed in PubMed (PMID 24642024). Copyright the publisher.